Tilt-Up Concrete Load-Bearing Walls, Caulked and Painted Both Sides
TI ELECTRICAL:
TI Will Include Outlets Between Every Other Dock Door
STAIRS:
Galvanized Dock Stairs
ROOFING:
60-Mil TPO Roofing, Mechanically Fastened with R-24
ROOF DECKING:
White Primed Roof Decking, Pinned to Joists, Columns Painted
WINDOWS:
Skylights, 4'x8' Prismatic, Every Other Central Bay, Clerestory Load Bay Windows
DOCK DOORS:
22 Dock Doors Per Building, Vertical Lift, 3” Track w Z-Guards, View Window, Bumpers
DRIVE-IN DOORS:
Two Drive-Up Ramps Per Building with 12’x14’ Vertical Lift Doors
FIRE PROTECTION:
ESFR Fire Sprinkler Systems, Interior Pressurized Loop. Fire Alarm Monitor’s Flow and Tamper Switches, Only
VENTILATION:
Unit Heaters for Freeze Protection + 1.5 Air Changes Per Hour Ventilation via Intake LouversUnit Heaters for Freeze Protection + 1.5 Air Changes Per Hour Ventilation via Intake Louvers
WAREHOUSE LIGHTING:
All lighting is LED including Cooper Metalux High Bay, 25 Foot Candles Ave Min
ELECTRICAL SERVICE:
480 Volt 3-Phase Power – Ampacity Available for Any Load Required